Issue Info: 
  • Year: 

    2001
  • Volume: 

    14
  • Issue: 

    3 (28)
  • Pages: 

    30-36
Measures: 
  • Citations: 

    0
  • Views: 

    1186
  • Downloads: 

    0
Abstract: 

Polymerization shrinkage of light cure composite resins causes many complications in conservative and esthetic restorations. The objective of this in-vitro study was to evaluate the polymerization shrinkage, degree of conversion and the amount of filler in IDM and tetric ceram composites. Ten disks shaped, uncured specimens (8mm×1.547mm) of each composite were placed on glass slide in the center of the metal attached to it. Then specimens were light cured for 60s from underneath. After 30 minutes, the thickness of specimens, using a micrometer and the percent of the polymerization shrinkage of each sample were measured. Statistical analysis was carried out by t-test (P<0.05). Also the degree of conversion of specimens was evaluated with FTIR and the mineral filler content was measured by burning in electric oven. Polymerization shrinkage in IDM and tetric ceram was not significantly different. Degree of conversion and mineral filler content in tetric ceram was greater than that of IDM. It is assumed that the low degree of conversion in IDM is due to its chemical composition and filler content. Also, the similarity in linear polymerization shrinkage between IDM and tetric ceram may be caused by the low degree of conversion in IDM.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 1186

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Author(s): 

PAHLAVAN A. | BANAVA S.

Issue Info: 
  • Year: 

    2004
  • Volume: 

    16
  • Issue: 

    4 (37)
  • Pages: 

    5-15
Measures: 
  • Citations: 

    0
  • Views: 

    1906
  • Downloads: 

    0
Abstract: 

Statement of Problem: Composite reins have recently become popular for posterior teeth restorations.Gap formation and subsequent microleakage are of the complications resulting from such restorations.One of the techniques to overcome polymerization shrinkage of composite resins is sandwich technique (application of glass ionomer as a base beneath the composite resin). Since polymerization patterns in two types of composite resins (light cure and self cure) differ from each other, various effects on the bond strength between glass ionomer and dentin are expected.Purpose: The aim of this in vitro study was to evaluate the effects of self- cure and light- cure composite resins in sandwich technique on the bond strength of light cure glass ionomer and dentin.Materials and Methods: 40 extracted human premolars were selected and divided into four groups:Group 1: Light cure glass ionomer of 1mm thickness was placed on dentin.Group 2: 1mm thickness of light cure glass ionomer plus a mass of self cure composite resin of 2mm thickness were placed.Group 3: 1mm thickness of light cure glass ionomer plus light cure composite resin as two separate 1mm layer were placed.Group 4: 1mm thickness of light cure glass ionomer with 37% phosphoric acid etching followed by two separate layers of light cure composite resin of 1mm thickness were placed.SEM was used to determine gap size at GI- dentin and GI- composite interfaces. The findings were analyzed by ANOVA and t-student tests.Results: Groups 1 and 2 showed no gap at GI-dentin interface and also cracks were not observed in all these specimens. In group 3, there was gap between light cure GI and light cure composite resin and cracks were seen in GI, too. Group 4 showed gap at both interfaces and more cracks were seen in GI. Groups 1 and 2 showed the least gap formation and group 4 showed the most. Statistically significant difference was found between groups 3, 4 and group 1 (control), 2.Conclusion: Base on this study, the application of self-cure composite resin on light cure GI showed no gap and crack formation on GI-dentin and GI-composite interfaces and GI itself. However, light cure composite resins and glass ionomer etching aggregated crack and gap formation.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 1906

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Author(s): 

ALRAHMAN M.S.A.

Issue Info: 
  • Year: 

    2016
  • Volume: 

    4
  • Issue: 

    10
  • Pages: 

    0-0
Measures: 
  • Citations: 

    1
  • Views: 

    152
  • Downloads: 

    0
Keywords: 
Abstract: 

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 152

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2008
  • Volume: 

    21
  • Issue: 

    2 (55)
  • Pages: 

    116-123
Measures: 
  • Citations: 

    0
  • Views: 

    829
  • Downloads: 

    0
Abstract: 

Background and Aim: Microleakage has been always a major concern in restorative dentistry. The curing contraction of composites still presents a problem with controlling microleakage and postoperative sensitivity. The aim of this study was to investigate the effect of flowable and dual-cure resin composite liners on gingival microleakage of packable resin composite restorations.Materials and Methods: Sixty class II cavities with cervical margins 1 mm below the CEJ were prepared in 30 extracted human molars. The teeth were randomly divided into five groups of 12 each. In control group, each tooth was restored incrementally with Tetric Ceram composite without applying any liner. In the second and forth groups, flowable materials-Tetric Flow and dual-cure composite resin cement Relay X ARC were placed respectively as a 1-mm thick gingival increment and cured before the resin composite restoration, whereas, in the third and fifth groups liners were cured with the first increment of packable composite.The restored teeth were stored for one week in distilled water at 37oC, and thermocycled between 5oC and 55oC, sealed with nail varnish except the tooth – composite interface in cervical restoration margins and immersed in 2% basic fuchsin for 24 hours. Dye penetration was evaluated using a stereomicroscope with 28x magnification. The data were analyzed by Kruskal-Wallis and Mann-Whitney U-tests with p<0.05 as the level of significance.Results: The results of this study indicated that there were significant statistical differences between controlcured flowable liner, control-flowable liner without separately curing, control-cured dual cure composite resin cement groups.However there were no significant differences between dual-cure composite resin cement without separately curing and control, cured flowable liner and cured dual cure composite resin cement, flowable liner without separately curing and dual cure composite resin cement without separately curing groups.Conclusion: The results of this study indicated that none of techniques could thoroughly eliminate microleakage in gingival floor, however the effect of flowable or a dual-cure liner on reducing the gingival microleakage was found to be statistically significant in tested restorative material.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 829

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2021
  • Volume: 

    31
  • Issue: 

    202
  • Pages: 

    116-125
Measures: 
  • Citations: 

    1
  • Views: 

    141
  • Downloads: 

    0
Abstract: 

Background and purpose: In orthodontic brackets, unlike restorative materials or porcelain, the shear bond strength of the adhesives used is important because the oblique forces from food or objects or the tension of the adhesive food affect the brackets. This study aimed at measuring and comparing shear bond strength and adhesive remnant index of light cure composite, no mix (self-cure) composite, and no bond composite (GC Orthoconnect). Materials and methods: A total of 27 non-carious and sound human premolar teeth were used. The samples were divided into three groups, including light cure composite, self-cure composite, and no bond composite (GC Orthoconnect). After bonding and thermocycling process, the metal brackets (American Orthodontics) were then debonded using universal testing machine. Adhesive remnant index (ARI) score was assessed. Results: The highest and lowest SBS mean values were seen in self-cure group (18. 0402±, 5. 71665) and light cure group (7. 7890±, 3. 98995), respectively. There were significant differences in SBS values between all groups except between the no bond group and the self-cure group (P= 0. 18, P>0. 05). The highest ARI scores were 0 in the self-cure group and 3 in the no bond group and the light cure group. Conclusion: The no bond composite provided acceptable overall shear bond strength and compared to light cure composite showed higher shear bond strength and lower bond failure.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 141

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Author(s): 

MOAZAMI S.M. | FALAH M.

Issue Info: 
  • Year: 

    2004
  • Volume: 

    28
  • Issue: 

    1-2
  • Pages: 

    105-110
Measures: 
  • Citations: 

    1
  • Views: 

    820
  • Downloads: 

    0
Abstract: 

Introduction: The reaction of polymerization can be controlled by the light exposure pattern and the temperature. The purpose of this study was to evaluate the effect of different light exposure patterns and composite temperatures on micro leakage of light cured composite resin restorations. Materials and Methods: In this interventional study, class V cavities were prepared on 200 extracted human molars. Then the teeth were randomly divided into four main groups according to different light exposure patterns of High Intensity Program (HIP), Low Intensity program(LOP), Pulls Program(PUL) and Suggested Progressive Program(SUP) . and 5 subgroups according to different temperatures of composite during curing (5°c, 20°c, 35°c, 50°c and 65°c). After thermo cycling and dye penetration, measurement of micro leakage was done using a stereomicroscope. The data were analyzed using SPSS software (ANOVA).Results: ANOV A showed that both in enamel and dentinal margins, a significant decrease in micro leakage has occurred in SUP group. Micro leakage in enamel and dentinal margins was significantly higher in HIP group than the other groups. No significant difference was observed in the rate of micro leakage among the 5 subgroups with different temperatures.Conclusion: SUP light curing pattern could be considered for improving composite resin restorations as a superior light exposure pattern due to its ability in Polymerization control, reducing polymerization shrinkage stress and micro leakage. Prewar Ming of the composites is a practical and easy way to improve composite properties for dental restorations.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 820

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2008
  • Volume: 

    21
  • Issue: 

    2 (55)
  • Pages: 

    90-99
Measures: 
  • Citations: 

    0
  • Views: 

    817
  • Downloads: 

    0
Abstract: 

Background and Aim: Nonmetallic tooth- colored posts adhere to canal walls by dentin bonding agents and resin cements. Better retention and proper distribution of stress result from enough and proper bonding. The purpose of this study was to evaluate bond strength of D.T. Light - post with two different resin cements (selfcure & dual-cure) and to investigate the effect of irrigating solutions applied in root canal on bond strength of the resin cements and D.T.Light- post to root canal wall.Materials and Methods: In this experimental study 40 single root teeth (maxillary canine & central) were selected and stored in 0.1% thymol solution for one week and transferred to distilled water. The teeth were decoronated 2mm above CEJ. The canal space was mechanically enlarged using k-files (up to # 70). The teeth were randomly divided into two groups. The first group was irrigated with 2.6% NaOCl, and the second was irrigated with normal saline. After drying, the teeth were filled with gutta percha cones using lateral condensing method. After two weeks the post space was prepared and D.T.Light- post was inserted in each subgroup using self or dual-cure cements according to manufacturer's instructions. After thermocycling, the apical part was cut 1cm below CEJ. The remained length was divided into 9 equal sequential sections. Each section was submitted to shear push-out test in universal testing machine. Statistical analysis of the bond strength data was performed using ANOVA and post hoc tests with p<0.05 as the level of significance. All failed specimens were examined under stereomicroscope. Degrees of conversion (DC) of the cements were determined by FTIR.Results: Significant difference in bond strength values were found among sites (P=0.001) and cements (P=0.03). With increasing in depth, bond strength decreased. The mean bond strength value in dual-cure resin cement was higher than self-cure cement. The irrigating solutions caused no significant difference in bond strength (P=0.46). DC% had significant difference in various depths.Conclusion: According to the results of this investigation, bond strength of dual-cure cement is higher than self-cure one in D.T Light- post because of post's translucency. 2.6% sodium hypochlorite does not affect the bond strength.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 817

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 1
Author(s): 

Issue Info: 
  • Year: 

    2018
  • Volume: 

    4
  • Issue: 

    1
  • Pages: 

    12-16
Measures: 
  • Citations: 

    1
  • Views: 

    83
  • Downloads: 

    0
Keywords: 
Abstract: 

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 83

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    0
  • Volume: 

    17
  • Issue: 

    3
  • Pages: 

    23-27
Measures: 
  • Citations: 

    0
  • Views: 

    236
  • Downloads: 

    0
Abstract: 

مقدمه: در این پژوهش، با توجه به اهمیت یافتن روز افزون کامپوزیت ها و همچنین تاثیر امواج فروسرخ بر خواص پلیمرها تاثیرات حذف و افزایش تابش فرو سرخ بر خواص مکانیکی کامپوزیت های دندانی مورد بررسی قرار گرفته است. روش بررسی: در این مطالعه تجربی _ آزمایشگاهی از 2 نوع دستگاه لایت کیور هالوژن (دستگاه لایت کیور optilux متعلق به شرکت Kerr) و LED (دستگاه لایت کیور woodpecker LED. D) و از کامپوزیت z250 ساخت شرکت 3mاستفاده شد. تعداد 54 عدد قالب کامپوزیت به ابعاد (ارتفاع 2 میلی متر و طول 15 میلی متر و عرض 5/3 میلی متر) در 6 گروه (QTH بدون تغییر، LED بدون تغییر، QTH به همراه فیلتر حذف کننده کامل طیف فروسرخ، LED به همراه فیلتر حذف کننده کامل طیف فروسرخ، QTH همراه با تابش فروسرخ با طول موج 980 نانومتر) به میزان 6 ژول بر سانتی متر مربع، LED همراه با تابش فروسرخ با طول موج 980 نانومتر (به میزان 16 j/cm2) تهیه شد که با در نظر گرفتن انرژی مورد نیاز (16 j/cm2) بر مبنای رادیومتر اختصاصی دستگاه های لایت کیور قالب ها در شرایط ثابت محیط، کیور شدند. سپس نمونه ها تحت آزمون خمش سه نقطه ای قرار گرفتند و استحکام خمشی، مدول خمشی و چقرمگی خمشی این نمونه ها محاسبه گردید. یافته ها: یافته های این پژوهش نشان دهنده این بودند که با حذف کامل طیف IR و اعمال دانسیته انرژی مساوی (با تغییر فاکتور زمان)، استحکام خمشی دو گروه LED و QTH افزایش پیدا می کرد که این افزایش به لحاظ آماری قابل توجه بوده است. این نتایج همچنین نشان داده اند در گروه هایی که تحت تابش IR اضافی قرار گرفته اند نیز اندکی افزایش در هر دو گروه LED و QTH مشاهده گردید که البته این میزان به لحاظ آماری قابل توجه نبوده است. نتایج متغیر مدول خمشی نیز بیانگر آن است که افزایش یا کاهش طیف IR در درون گروه ای QTH و LED تفاوت محسوسی در میزان مدول الاستیک ایجاد نکرده است و این تغییرات به لحاظ آماری قابل توجه نبوده است. نتایج بررسی چقرمگی نیز بیانگر آن است که چقرمگی در گروه های دارای فیلتر حذف کننده IR با دو گروه دیگر تفاوت قابل توجهی پیدا کرده است و این تفاوت به لحاظ آماری معنی دار است. در این متغیر در درون گروه های QTH و LED بدون تغییر و گروه های تحت تابش IR اضافی تفاوت قابل توجه آماری دیده نشده است. نتیجه گیری: نتیجه های این پژوهش حاکی از آن می باشد که حذف کامل IR با حفظ دانسیته انرژی به باز آرایی بهتر پیوند های درون ماده کمک می کند که سبب بهبود کلی خواص فیزیکی کامپوزیت می گردد.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 236

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2012
  • Volume: 

    1
  • Issue: 

    1
  • Pages: 

    32-35
Measures: 
  • Citations: 

    0
  • Views: 

    213
  • Downloads: 

    77
Abstract: 

Introduction: The degree of polymerization depends on the type of light-curing unit. The aim of this study was to compare the hardness of composite resin cured by LED and Halogen light curing units.Methods: In this experimental study, 20 cylindrical samples of Tetric Ceram composite were prepared. Half of them were cured with Ultralume 2 LED and the other half with Astralis 7 Halogen light curing unit. In the depths of 0, 1, 2 and 3 mm from surface, one point in peripheral and one point in central portion were marked, then the hardness of these points was measured by Vickers test. The data was analyzed by a pvalue less than 0.05 considered as significant.Results: The mean hardness of samples cured by LED was more than halogen group in different depths and this difference was statistically significant in peripheral points (p=.048) but this was not significant in central points (p=0.644). The mean hardness in both groups had a decreasing trend from surface to the deep parts in central and peripheral parts and this was more in the central parts.Conclusions: Composites cured by LED light curing unit showed more hardness in similar depths, besides the hardness of composites in central parts is more than the peripheral ones in both groups.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 213

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 77 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
litScript
telegram sharing button
whatsapp sharing button
linkedin sharing button
twitter sharing button
email sharing button
email sharing button
email sharing button
sharethis sharing button